Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 294
Filter
1.
Rev. bras. ortop ; 58(1): 67-71, Jan.-Feb. 2023. tab, graf
Article in English | LILACS | ID: biblio-1441342

ABSTRACT

Abstract Objective To compare the measurement of patellar height in the pre- and postoperative period of total knee arthroplasties (TKAs) and its variation in patients with and without patellar replacement. Methods Retrospective evaluation of radiographs of patients submitted to TKA between 2014 and 2020. Profile radiographs were evaluated using the modified Caton-Deschamps patellar height index, comparing the pre- and postoperative measurements of 90 patients, with a total of 100 knees. Next, two groups were compared with a different surgical technique, considering the replacement or not of the patella. All patients who had x-rays evaluated had indication of TKA by osteoarthrosis without previous procedures that could interfere at patellar height. Results The statistical analysis showed a statistically significant difference, with the preoperative index superior to the postoperative rate, evidencing an overall decrease in patellar height. The Caton-Deschamps index modified for mean preoperative TKA was 1.41 (±0.25), and it was 1.31 (± 0.25), p< 0.001for postoperative TKA. No significant difference was found in the variation of this index when comparing the groups with and without patellar replacement. The mean difference of the index in the group without patella was 0.11, and 0.08 in the group with patella, and this difference was considered nonsignificant, p= 0.510. Conclusion We can conclude that patellar height had significant variation in the total group, with reduction of patellar height in the postoperative period. However, the height did not vary significantly between the postoperative groups with and without patellar replacement, regardless of the choice of the surgeon.


Resumo Objetivo Comparar a medida da altura patelar no pré- e pós-operatório das artroplastias totais do joelho (ATJs) e sua variação nos pacientes com e sem substituição patelar. Métodos Avaliação retrospectiva de radiografias de pacientes submetidos a ATJ entre 2014 e 2020. Foi feita a avaliação de radiografias em perfil, usando o índice de altura patelar de Caton-Deschamps modificado, comparando as medidas do pré- e pós-operatório de 90 pacientes, totalizando 100 joelhos. A seguir, foi feita a comparação de dois grupos, com técnica cirúrgica distinta, considerando a substituição ou não da patela. Todos os pacientes que tiveram radiografias avaliadas tiveram indicação de ATJ por osteoartrose sem procedimentos prévios que pudessem interferir na altura patelar. Resultados A análise estatística demonstrou uma diferença estatisticamente significativa, sendo o índice pré-operatório superior ao pós-operatório; evidenciando um abaixamento global da altura patelar. O índice Caton-Deschamps modificado para ATJ pré-operatório médio foi de 1,41 (±0,25), e o pós foi de 1,31 (±0,25), p< 0,001. Não foi encontrada diferença significativa na variação deste índice quando comparados os grupos com e sem substituição patelar. A diferença média do índice no grupo sem patela foi de 0,11 e no grupo com patela foi de 0,08, sendo esta diferença considerada não significativa, p= 0,510. Conclusão Podemos concluir que a altura patelar teve variação significativa no grupo total, com redução da altura patelar no pós-operatório. Entretanto, a altura não variou de forma significativa entre os grupos pós-operatórios com e sem substituição patelar, independentemente da opção do cirurgião.


Subject(s)
Humans , Patella/surgery , Arthroplasty, Replacement, Knee , Knee Prosthesis
2.
China Journal of Orthopaedics and Traumatology ; (12): 507-513, 2023.
Article in Chinese | WPRIM | ID: wpr-981724

ABSTRACT

OBJECTIVE@#To evaluate outcomes of mixed unicompartmental knee arthroplasty(UKA) and total knee arthroplasty(TKA) in the treatment of medial osteoarthritis(OA) of the knee.@*METHODS@#Retrospective analysis of 156 patients, 44 males and 112 females, aged from 50 to 75 years old with an average of(58.76±4.97) years old, who underwent knee arthroplasty from October 2017 to October 2019. The patients were divided into two groups:81 cases(81 knees) underwent TKA, including 23 males and 58 females, aged from 51 to 75 years old with an average of (58.60±5.01) years old, and 75 case (75 knees) underwent UKA with mixed phase 3 Oxford, including 21 males and 54 females, aged from 50 to 72 years old with an average of (58.92±4.95) years old. The two groups were compared regarding to the clinical outcomes, assessed using surgical information and complications, American Knee Society score(AKSS) clinical score and functional score. Radiographs were assessed using hip-knee-ankle angle(HKA), tibial component valgus/varus angle(TCVA), tibial component posterior slope angle(TCPSA), femoral component valgus/varus angle(FCVA), femoral component posterior slope angle(FCPSA), looking for bearing dislocation, prosthesis loosening, progression of OA in lateral compartment.@*RESULTS@#Intraoperative bleeding, operative time and hospital days were significantly better in the UKA group than in the TKA group (P<0.05), and there were no postoperative complications in either group. Patients in both groups were enrolled with an average follow-up time of (38.01±8.90) months, ranged from 24 to 54 months. AKSS functional, AKSS clinical, HKA in both groups significantly improved at the final follow-up compared with those before operation. At the final follow-up, the UKA group was significantly better than the TKA group in AKSS functional and AKSS clinical, whereas HKA in the TKA group was better. At the final follow-up. TCVA and FCVA between the two groups were not significantly different, while TCPSA and FCPSA in the UKA group were significantly greater than the TKA group. No signs of progression of OA to the lateral compartment were observed.@*CONCLUSION@#Mixed phase 3 Oxford UKA in medial unicompartmental knee osteoarthritis was considerably better than TKA for less blood loss, shorter operation time, shorter hospital stay, rapid postoperative recovery, helping achieve satisfactory function, provided satisfactory outcome.


Subject(s)
Male , Female , Humans , Middle Aged , Aged , Arthroplasty, Replacement, Knee , Osteoarthritis, Knee/surgery , Retrospective Studies , Treatment Outcome , Knee Joint/surgery , Knee Prosthesis
3.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 647-652, 2023.
Article in Chinese | WPRIM | ID: wpr-981646

ABSTRACT

OBJECTIVE@#To investigate the short- and mid-term effectiveness of unicompartmental knee arthroplasty (UKA) for post-traumatic arthritis (PTA) of knee.@*METHODS@#The clinical data of 30 patients with PTA of unilateral knee between March 2014 and September 2021 was retrospectively analyzed. There were 14 males and 16 females with an average of 64.5 years (range, 33-81 years). The average body mass index was 26.7 kg/m 2 (range, 19.8-35.6 kg/m 2). The types of injuries that caused PTA included intra-articular fracture in 16 cases, extra-articular fracture in 8 cases, and soft tissue injury in 6 cases. The initial injuries were treated by conservative therapy in 12 cases and by surgical therapy in 18 cases. Ten cases were medial compartment osteoarthritis and 20 cases were lateral compartment osteoarthritis. According to Kellgren-Lawrence staging, there were 19 cases of grade Ⅲ and 11 cases of grade Ⅳ. The operative time, the length of hospital stay, complications, and subjective satisfaction were recorded. The Oxford Knee Function Score (OKS), Hospital for Special Surgery (HSS) score, and knee range of motion (ROM) were used to evaluate knee function. Weight-bearing X-ray films were taken to measure the femoro-tibial angle (FTA) and to assess alignment correction of the lower limb.@*RESULTS@#The operative time ranged from 50 to 95 minutes (mean, 63.7 minutes), the length of hospital stay ranged from 3 to 8 days (mean, 6.9 days). Superficial infection occurred in 2 patients, while the remaining incisions healed by first intention. There was no deep vein thrombosis or neurovascular injury. All patients were followed up 17-109 months (median, 70 months). At last follow-up, OKS score, HSS score, and ROM in 30 cases significantly improved when compared with those before operation (P<0.05). Lower limb alignment was significantly corrected and there was significant difference in FTA of the varus and valgus knees between pre- and post-operation ( P<0.05). The patient satisfaction rate was 86.7% (26/30). Two cases developed contralateral osteoarthritis progression during follow-up. No bearing dislocation, prosthesis loosening or sinking occurred and none required further revision.@*CONCLUSION@#For patients with PTA of knee, UKA can obtain definite short- and mid-term effectiveness with high patient satisfaction.


Subject(s)
Male , Female , Humans , Arthroplasty, Replacement, Knee , Retrospective Studies , Knee Prosthesis , Osteoarthritis, Knee/surgery , Treatment Outcome , Knee Joint/surgery , Lower Extremity/surgery , Range of Motion, Articular
4.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 404-409, 2023.
Article in Chinese | WPRIM | ID: wpr-981606

ABSTRACT

OBJECTIVE@#To compare the short-term effectiveness of "SkyWalker" robot-assisted total knee arthroplasty (TKA) and traditional TKA.@*METHODS@#A clinical data of 54 patients (54 knees) with TKA who met the selection criteria between January 2022 and March 2022 was retrospectively analyzed. Among them, 27 cases underwent traditional TKA (traditional operation group) and 27 cases underwent "SkyWalker" robot-assisted TKA (robot-assisted operation group). There was no significant difference between the two groups ( P>0.05) in terms of gender, age, body mass index, osteoarthritis side, disease duration, and preoperative Knee Society Score (KSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC), visual analogue scale (VAS) score, hip-knee-ankle angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and posterior proximal tibial angle (PPTA). The operative time, intraoperative bleeding volume, surgery-related complications, the KSS, WOMAC, and VAS scores before operation and at 6 months after operation, and Forgotten Joint Score (FJS) at 6 months after operation were recorded. X-ray films were taken to review the prosthesis position and measure HKA, LDFA, MPTA, and PPTA. The differences of the clinical and imaging indicators between before and after operation were calculated and statistically analyzed.@*RESULTS@#The operations were completed successfully in both groups. There was no significant difference in the operative time and intraoperative bleeding volume between the two groups ( P>0.05). After operation, 1 case of incision nonunion and 1 case of heart failure occurred in the traditional operation group, while no surgery-related complications occurred in the robotic-assisted operation group. The incidences of surgical complications were 7.4% (2/27) in the traditional operation group and 0 (0/27) in the robotic-assisted operation group, with no significant difference ( P=0.491). Patients in both groups were followed up 6 months. KSS score, WOMAC score, VAS score, and ROM significantly improved in both groups at 6 months after operation when compared with preoperative ones ( P<0.05). There was no significant difference between the two groups ( P>0.05) in the differences between the pre- and post-operative values of the clinical indicators and FJS scores at 6 months after operation. X-ray films showed that the lower extremity force lines of the patients improved and the knee prostheses were in good position. Except for LDFA in the robot-assisted operation group, HKA, LDFA, MPTA, and PPTA significantly improved in both groups at 6 months after operation when compared with the preoperative ones ( P<0.05). There was no significant difference between the two groups in the differences between the pre- and post-operative values of the radiological indicators ( P>0.05).@*CONCLUSION@#The "SkyWalker" robot-assisted TKA is one of the effective methods for the treatment of knee osteoarthritis and had good short-term effectiveness. But the long-term effectiveness needs to be further studied.


Subject(s)
Humans , Arthroplasty, Replacement, Knee/methods , Knee Joint/surgery , Knee Prosthesis , Osteoarthritis, Knee/surgery , Retrospective Studies , Robotics , Treatment Outcome
5.
Journal of Biomedical Engineering ; (6): 508-514, 2023.
Article in Chinese | WPRIM | ID: wpr-981569

ABSTRACT

The surgical installation accuracy of the components in unicompartmental knee arthroplasty (UKA) is an important factor affecting the joint function and the implant life. Taking the ratio of the medial-lateral position of the femoral component relative to the tibial insert (a/A) as a parameter, and considering nine installation conditions of the femoral component, this study established the musculoskeletal multibody dynamics models of UKA to simulate the patients' walking gait, and investigated the influences of the medial-lateral installation positions of the femoral component in UKA on the contact force, joint motion and ligament force of the knee joint. The results showed that, with the increase of a/A ratio, the medial contact force of the UKA implant was decreased and the lateral contact force of the cartilage was increased; the varus rotation, external rotation and posterior translation of the knee joint were increased; and the anterior cruciate ligament force, posterior cruciate ligament force and medial collateral ligament force were decreased. The medial-lateral installation positions of the femoral component in UKA had little effect on knee flexion-extension movement and lateral collateral ligament force. When the a/A ratio was less than or equalled to 0.375, the femoral component collided with the tibia. In order to prevent the overload on the medial implant and lateral cartilage, the excessive ligament force, and the collision between the femoral component and the tibia, it is suggested that the a/A ratio should be controlled within the range of 0.427-0.688 when the femoral component is installed in UKA. This study provides a reference for the accurate installation of the femoral component in UKA.


Subject(s)
Humans , Arthroplasty, Replacement, Knee , Knee Joint/surgery , Knee Prosthesis , Gait , Rotation
6.
China Journal of Orthopaedics and Traumatology ; (12): 151-156, 2023.
Article in Chinese | WPRIM | ID: wpr-970837

ABSTRACT

OBJECTIVE@#To investigate the clinical efficacy of unicompartmental knee arthroplasty (UKA) in the treatment of knee osteoarthritis in patients over 75 years old.@*METHODS@#The clinical efficacy of primary fixed platform UKA in patients with osteoarthritis, was retrospectively analyzed from October 2014 to November 2020. Age, body mass index (BMI), range of motion (ROM), preoperative joint function score, the quality of life score and other preoperative indicators were measured by propensity score matching (PSM). The patients were divided into elderly group (≥75 years old) and control group (<75 years old). Oxford knee score(OKS), Western Ontario McMaster Universities osteoarthritis index(WOMAC), Short Form-12 including physical component summary (PCS), mental component summary(MCS), minimal clinically important difference(MCID ) and clinical complications were evaluated preoperatively and postoperatively.@*RESULTS@#A total of 514 patients were analyzed, 428 patients fulfilled the inclusion criteria. A propensity-score matching study was conducted to eliminate confounding factors. After 1∶2 propensity match, there were 84 patients in elderly group (≥75 years), age ranged from 75 to 88 years old, with an average of (78.79±3.08) years old, and 168 patients in control group (<75 years), age ranged from 47 to 74 years old, with an average of (64.10±5.96)years old. The follow-up duration of two groups ranged from 12 to 84 months with an average of (29.35±16.52) months in elderly group, and 12 to 85 months with an average of (31.83±17.34) months in control group. There was only significant difference in age between the elderly and control groups preoperatively (P<0.01). Postoperatively, the elderly group showed significantly higher WOMAC (P<0.01) and lower SF-12 PCS scores (P<0.01) as compared to the control group. There was no significant difference between the elderly group and the control group in knee range of motion, OKS and the proportion of each scoring system reaching the minimum clinical difference value (P>0.05). In the aspect of preperative complications, the elderly group exhibited more surgical site complications and postoperative delirium compared to control group(P<0.05). The differences in other indicators including deep vein thrombosis, acute urinary retention, cardiovascular events, cerebrovascular events and radiolucent lines around prothesis were not statistically significant(P>0.05).@*CONCLUSION@#UKA in the treatment of elderly patients over 75 years old with knee osteoarthritis was safe and feasible, and could obtain satisfactory short-term efficacy.


Subject(s)
Humans , Aged , Aged, 80 and over , Middle Aged , Osteoarthritis, Knee/surgery , Knee Prosthesis , Retrospective Studies , Propensity Score , Quality of Life , Knee Joint/surgery , Arthroplasty, Replacement, Knee/methods , Treatment Outcome
7.
Chinese Medical Journal ; (24): 73-81, 2023.
Article in English | WPRIM | ID: wpr-970050

ABSTRACT

BACKGROUND@#Synovectomy has been introduced into total knee arthroplasty (TKA) with the aim of relieving pain and inflammation of the synovium. However, there are no long-term, comparative data to evaluate the effect of synovectomy in TKA. This study was aimed at assessing pain, function, and complications in patients undergoing synovectomy during TKA for osteoarthritis (OA) at long-term follow-up.@*METHODS@#This was a prospective randomized controlled trial of 42 consecutive patients who underwent staged bilateral TKA. Patients undergoing the first-side TKA were allocated to receive TKA with or without synovectomy followed by a 3-month washout period and crossover to the other strategy for the opposite-side TKA. The overall efficacy of both strategies was evaluated by determination of blood loss, the Knee Society score (KSS), and knee inflammation conditions during a 3-month postoperative period. The postoperative pain, range of motion (ROM), and complications were sequentially evaluated to compare the two groups until 10 years after surgery.@*RESULTS@#At the 10-year follow-up, both groups had a similarly significantly improved ROM (114.88 ± 9.84° vs. 114.02 ± 9.43°, t  = 0.221, P  = 0.815) and pain relief with no differences between the two groups (1.0 [1.0] vs. 1.0 [1.5], U  = 789.500, P  = 0.613). Similar changes in total blood loss, KSS, and knee inflammation were found in both groups during 3 months postoperatively ( P  > 0.05). Additionally, there was no significant difference regarding complications and satisfaction between the two groups ( P  > 0.05).@*CONCLUSIONS@#Synovectomy in conjunction with TKA for primary OA does not seem to provide any benefit regarding postoperative pain, ROM, and satisfaction during a 10-year follow-up. In addition, it may not result in more blood loss and increased incidence of long-term complications. Based on our long-term findings, it should not be performed routinely.@*TRIAL REGISTRATION@#Chinese Clinical Trial Registry, ChiCTR-INR-16008245; https://www.chictr.org.cn/showproj.aspx?proj=13334 .


Subject(s)
Humans , Arthroplasty, Replacement, Knee/methods , Synovectomy/methods , Osteoarthritis, Knee/surgery , Prospective Studies , Pain, Postoperative , Inflammation/etiology , Range of Motion, Articular , Knee Joint/surgery , Treatment Outcome , Knee Prosthesis/adverse effects
8.
Chinese Medical Journal ; (24): 1478-1484, 2023.
Article in English | WPRIM | ID: wpr-980926

ABSTRACT

BACKGROUND@#Total knee arthroplasty (TKA) can reduce severe joint pain and improve functional disability in hemophilia. However, the long-term outcomes have rarely been reported in China. Therefore, this study aimed to evaluate the long-term outcomes and complications of TKA in Chinese patients with hemophilic arthropathy.@*METHODS@#We retrospectively reviewed patients with hemophilia who underwent TKA between 2003 and 2020, with at least 10 years of follow-up. The clinical results, patellar scores, patients' overall satisfaction ratings, and radiological findings were evaluated. Revision surgery for implants during the follow-up period was recorded.@*RESULTS@#Twenty-six patients with 36 TKAs were successfully followed up for an average of 12.4 years. Their Hospital for Special Surgery Knee Score improved from an average of 45.8 to 85.9. The average flexion contracture statistically significantly decreased from 18.1° to 4.2°. The range of motion (ROM) improved from 60.6° to 84.8°. All the patients accepted patelloplasty, and the patients' patellar score improved from 7.8 preoperatively to 24.9 at the last follow-up. There was no statistically significant difference in clinical outcomes between the unilateral and bilateral procedures, except for a better ROM at follow-up in the unilateral group. Mild and enduring anterior knee pain was reported in seven knees (19%). The annual bleeding event was 2.7 times/year at the last follow-up. A total of 25 patients with 35 TKAs were satisfied with the procedure (97%). Revision surgery was performed in seven knees, with 10- and 15-year prosthesis survival rates of 85.8% and 75.7%, respectively.@*CONCLUSIONS@#TKA is an effective procedure for patients with end-stage hemophilic arthropathy, which relieves pain, improves knee functions, decreases flexion contracture, and provides a high rate of satisfaction after more than ten years of follow-up.


Subject(s)
Humans , Arthroplasty, Replacement, Knee/methods , Hemophilia A/surgery , Follow-Up Studies , Retrospective Studies , Treatment Outcome , Knee Joint/surgery , Range of Motion, Articular , Arthritis/complications , Pain , Contracture/surgery , Surgeons , Knee Prosthesis
9.
Chinese Medical Journal ; (24): 1539-1550, 2023.
Article in English | WPRIM | ID: wpr-980814

ABSTRACT

BACKGROUND@#Patellofemoral joint (PFJ) degeneration has traditionally been regarded as a contraindication to unicompartmental knee arthroplasty (UKA). More recently, some researchers have proposed that PFJ degeneration can be ignored in medial UKA, and others have proposed that this change should be reviewed in PFJ degenerative facets and severity. This study aimed to systematically evaluate the effect of PFJ degeneration on patient-reported outcome measures (PROMs) and revision rates after medial UKA.@*METHODS@#Electronic databases (PubMed, Embase, Web of Science, etc.) were searched for studies assessing the influence of PFJ degeneration on medial UKA. A random-effects meta-analysis was conducted for the Oxford knee score (OKS), Knee society score (KSS), and revision rates and stratified by PFJ degenerative facets (medial/lateral/trochlear/unspecified), severe PFJ degeneration (bone exposed), and bearing type (mobile/fixed). Heterogeneity was assessed by the Cochran Q test statistic and chi-squared tests with the I-squared statistic.@*RESULTS@#A total of 34 articles with 7007 knees (2267 with PFJ degeneration) were included (5762 mobile-bearing and 1145 fixed-bearing and 100 unspecified). Slight to moderate degenerative changes in the medial and trochlear facets did not decrease the OKS and KSS, and only lateral facets significantly decreased the OKS (mean difference [MD] = -2.18, P   <  0.01) and KSS (MD = -2.61, P   <  0.01). The severity degree of PFJ degeneration had no additional adverse effect on the OKS, KSS, or revision rates. For mobile-bearing UKA, only lateral PFJ degeneration significantly decreased the OKS (MD = -2.21, P  < 0.01) and KSS (MD = -2.44, P  < 0.01). For fixed-bearing UKA, no correlation was found between PROMs/revision rates and PFJ degeneration.@*CONCLUSION@#For medial mobile-bearing UKA, slight to moderate degenerative changes in the PFJ, except lateral facet, did not compromise PROMs or revision rates. For medial fixed-bearing UKA, although it might not be conclusive enough, PROMs or revision rates were not adversely affected by PFJ degeneration (regardless of the facet).


Subject(s)
Humans , Arthroplasty, Replacement, Knee , Patellofemoral Joint/surgery , Treatment Outcome , Osteoarthritis, Knee/surgery , Knee Prosthesis , Bone Diseases , Knee Joint/surgery , Retrospective Studies
10.
Rev. bras. ortop ; 57(5): 734-740, Sept.-Oct. 2022. tab, graf
Article in English | LILACS | ID: biblio-1407689

ABSTRACT

Abstract Objective The management of bone loss represents a challenge in revisions of total knee arthroplasty (rTKA) and in complex primary total knee arthroplasties (TKAs). The purpose of the present study was to evaluate the midterm outcomes (5-year minimum follow-up) of knee reconstructions with tantalum trabecular metal (TM) cones on bone defects Anderson Orthopaedics Research Institute (AORI) 2 and 3. Materials and MethodsA retrospective analysis of the medical records of patients operated on between July 2008 and November 2014 was performed, collecting the following data: age, gender, laterality, body mass index, etiology of arthrosis, comorbidities, AORI classification of bone defects, causes for revision, readmissions, reoperations, perioperative and postoperative complications, radiographic signs of osteointegration, and maintenance of the TM support. Results A total of 11 patients with a mean follow-up of 7.28 years (standard deviation [SD] = 1.88; range = 5.12-10 years) was evaluated, with 1 patient operated upon for a primary arthroplasty, 6 for revision arthroplasties, and 4 for a second revision arthroplasty (re-revision). There were complications with the surgical wound, injury to the extensor mechanism and loosening of the femoral component in three of the patients that led to the necessity of four procedures due to complications with the surgical wound, injury to the extensor mechanism and loosening of the femoral component. Radiological signs of osteointegration of the trabecular cones were observed in all patients. We did not observe migration of the TM cones or the prosthetic components in the sample. Conclusion The tantalum metaphyseal cones were able to provide efficient structural support to prosthetic implants with radiographic signs of osteointegration in the medium term.


Resumo Objetivo O manejo da perda óssea representa um grande desafio em cirurgias de revisão de artroplastia do joelho (rATJ) e em artroplastias totais do joelho (ATJ) primárias complexas. O objetivo do presente estudo foi avaliar os resultados em médio prazo (seguimento mínimo de 5 anos) das reconstruções de joelho nas quais cones de metal trabecular (MT) de tântalo foram utilizados para tratamento de defeitos ósseos tipos 2 e 3, de acordo com a classificação proposta pela Anderson Orthopaedic Research Institute (AORI). Métodos Feita análise retrospectiva dos prontuários dos pacientes operados entre julho de 2008 e novembro de 2014, coletando-se os seguintes dados: idade, gênero, lateralidade, índice de massa corporal, etiologia da artrose, comorbidade, classificação AORI da falha óssea, causa da revisão da artroplastia total do joelho, reinternações, reoperações, complicações peri- e pós-operatórias, ocorrência de osteointegração radiográfica e manutenção da função de suporte do MT. Resultados Foram avaliados 11 pacientes com tempo médio de seguimento de 7,28 anos (desvio padrão [DP] = 1,88; variação = 5,12-10 anos), sendo que 1 paciente foi submetido a artroplastia primária, 6 a artroplastia de revisão e 4 a segunda revisão de artroplastia (re-revisão). Três pacientes necessitaram de quatro reoperações devido a complicações com a ferida operatória, a lesão do mecanismo extensor e a soltura do componente femoral. Sinais de osteointegração dos cones trabeculados foram observados em todos os pacientes. Não observamos migração do cone de MT ou dos componentes protéticos. Conclusão Os cones metafisários de tântalo foram capazes de prover suporte estrutural eficiente aos implantes protéticos com sinais radiográficos de osteointegração em médio prazo.


Subject(s)
Humans , Postoperative Complications , Tantalum , Retrospective Studies , Osseointegration , Outcome Assessment, Health Care , Arthroplasty, Replacement, Knee , Knee Prosthesis
11.
Rev. colomb. ortop. traumatol ; 36(1): 32-37, 2022. ilus.
Article in Spanish | LILACS, COLNAL | ID: biblio-1378778

ABSTRACT

Objetivo El genu valgo artrósico severo (> 20°) puede presentar distintos grados de insuficiencia del ligamento colateral medial e inestabilidad articular. El objetivo de este trabajo retrospectivo evalúa nuestra experiencia en el tratamiento del genu valgo severo con prótesis de estabilidad aumentada y propone un método para la evaluación y clasificación del genu valgo artrósico. Material y métodos A 27 pacientes (28 rodillas) con genu valgo artrósico severo se les realizó una artroplastia total de rodilla primaria con un implante de estabilidad aumentada, y un seguimiento promedio de 6.2 años. Se confeccionó una nueva clasificación del genu valgo artrósico que contempla la suficiencia ligamentaria y por lo tanto relaciona el tipo de rodilla con el tipo de implante necesario. Resultados Se utilizó una prótesis constreñida en 17 pacientes con un eje promedio de 22,7° y el ligamento colateral medial atenuado. En 11 casos con un eje promedio de 28,1°, LCM incompetente y/o recurvatum, se optó por bisagras rotatorias. Se confeccionó una nueva clasificación del genu valgo artrósico que considera el desgaste y estabilidad articular, el grado de deformidad de la rodilla y la suficiencia ligamentaria. Discusión Las prótesis constreñidas deben utilizarse en pacientes que presenten inestabilidad exclusivamente en el plano coronal, aún en genu valgo severo, con LCM atenuado. Debe reservarse el uso de bisagras rotatorias a aquellos pacientes que presentan incompetencia ligamentaria, inestabilidad combinada (recurvatum) y/o déficit neuro-muscular severo.


Purpose This retrospective level 2 analysis evaluates the prosthesis type selected in our department for the treatment of the severe valgus knee and proposes a new classification for the valgus knee osteoarthritis. Material and methods A total knee arthroplasty with a constrained or hinged knee prosthesis was performed in 28 valgus knees. The average follow-up was 6.2 years. A new classification that considerates the ligament sufficiency status was developed in order to relate the different knee types with the different type of eventually needed implants. Results Constrained prosthesis was used in 17 patients with an attenuated medial collateral ligament, and a rotating hinge in 11 patients with incompetent medial collateral ligament and/or recurvatum. The postoperatory Knee Society Score was of 85 points. The valgus knee was classified in 5 types considering the knee valgus deformity, the ligament sufficiency and joint stability and wear. Discussion The classification proposed clearly defines the ligament status and valgus knee types, and it seems to be a comprehensive tool to select the appropriate prosthesis. Constrained prosthesis must be used on patients who present coronal instability with attenuated medial collateral ligament. Rotating hinges must be reserved for those patients who have medial collateral ligament incompetence, recurvatum, combined instability and/or severe muscular deficiency.


Subject(s)
Humans , Genu Valgum , Joint Instability , Knee Prosthesis
12.
China Journal of Orthopaedics and Traumatology ; (12): 67-75, 2022.
Article in Chinese | WPRIM | ID: wpr-928269

ABSTRACT

OBJECTIVE@#To evaluate of the clinical effects of mobile-bearing(MB) and fixed-bearing(FB) unicompartmental knee arthroplasty(UKA) in the treatment of knee osteoarthritis by Meta-analysis.@*METHODS@#The literature on FB UKA and MB UKA in the treatment of knee osteoarthritis in PubMed, CNKI, Wanfang, Cochrane and EMBASE database were searched by computer from January 2000 to April 2020. According to the inclusion and exclusion criteria, two authors were selected independently and the selected literature was evaluated for quality.After literature data were extracted, Review Manager 5.3 software was used to analyze knee function score, postoperative activity, revision rate, polyethylene wear rate, pad dislocation, aseptic loosening, postoperative pain, knee arthritis progression, mechanical shaft alignment of lower limbs, and imaging clarity line respectively.@*RESULTS@#A total of 13 literatures were included in this meta-analysis, including 2 randomized controlled studies and 11 cohort studies. A total of 1 871 patients were included, including 913 in FB UKA group and 958 in MB UKA group. Meta analysis results showed that:postoperative knee joint function score[MD=-0.84, 95%CI(-1.46, -0.21), P=0.008] and postoperative knee joint range of motion [MD=-1.51, 95%CI(-2.84, -0.18), P=0.03] in FB UKA group were better than those in MB UKA group. Compared with FB UKA group, MB UKA group had a higher lower limb mechanical axis alignment rate[OR=2.08, 95%CI(1.27, 3.39), P=0.003], and the wear rate of polyethylene [OR=0.11, 95%CI(0.01, 0.91), P=0.04] was lower. There were no differences between two groups in the renovation rate [OR=1.16, 95%CI(0.75, 1.80), P=0.50), liner dislocation rate[OR=3.78, 95%CI(0.93, 15.29), P=0.06], aseptic loosening [OR=2.11, 95%CI(0.81, 5.51), P=0.13], postoperative pain[OR=1.13, 95%CI(0.37, 3.43), P=0.83], osteoarthritis progression[OR=1.28, 95%CI(0.67, 2.47), P=0.46)and imaging radiolucent line[OR=1.62, 95%CI(0.09, 30.22), P=0.75].@*CONCLUSION@#FB UKA has a higher postoperative functional score and range of motion.MB UKA has more advantages in the correction of lower limb mechanical axis, and the wear rate of polyethylene is also lower. There was no significant difference between the two groups in revision rate, dislocation of the liner, aseptic loosening, postoperative pain, progression of osteoarthritis, and postoperative translucency.


Subject(s)
Humans , Arthroplasty, Replacement, Knee , Knee Joint/surgery , Knee Prosthesis , Osteoarthritis, Knee/surgery , Prosthesis Design , Reoperation , Treatment Outcome
13.
China Journal of Orthopaedics and Traumatology ; (12): 54-58, 2022.
Article in Chinese | WPRIM | ID: wpr-928266

ABSTRACT

OBJECTIVE@#To investigate the effect of tibial coronal curvature on the alignment of tibial prosthesis in patients undergoing total knee arthroplasty (TKA).@*METHODS@#From July 2019 to April 2021, 100 patients with knee osteoarthritis were treated with total knee arthroplasty. Before operation, the full-length films of lower limbs were taken and the tibial bowing angle(TBA) was measured. TBA more than 2° was tibial bending, which was divided into tibial bending group and non bending group. There were 40 cases in tibial bending group, 9 males and 31 females, aged 56 to 84 years old with an average of (69.22±7.10) years. There were 60 cases in the non bending group, 19 males and 41 females, aged from 51 to 87 years old with an average of (70.80±7.21) years. The preoperative tibial length (TL) and medial proximal tibial angle (MPTA) were measured and compared between the two groups. The full-length X-rays of the lower limbs were taken again 3 days to 1 week after operation. The medial angle of the tibial component coronal aligement angle (TCCA) and the outilier rate of force line of the tibial prosthesis were measured and compared between the two groups. Pearson method was used to analyze the correlation between TCCA and age, TCCA and height, TCCA and weight, TCCA and BMI, TCCA and TBA, TCCA and TL, TCCA and MPTA; Spearman method was used to analyze the correlation between TCCA and gender, TCCA and Kellgren-Lawrence(K-L) grade.@*RESULTS@#All 100 patients successfully completed the operation and obtained satisfactory full-length X-rays in standing position. There was no significant difference in TL, MPTA and TCCA between bending group and non bending group(P>0.05). The outilier rate of force line in tibial bending group was 22.5%, and that in non bending group was 6.67%, the difference was statistically significant(P<0.05). The correlation study found that TCCA was strongly correlated with TBA(r=-0.702, P<0.01), weakly correlated with MPTA(r=0.311, P<0.01), and had no correlation with other parameters(P>0.05).@*CONCLUSION@#In patients with knee osteoarthritis undergoing total knee arthroplasty, tibial bending will lead to poor force line of tibial prosthesis. During operation, attention should be paid to osteotomy of proximal tibial vertical tibial mechanical axis and correct installation of prosthesis to avoid poor alignment of prosthesis.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Arthroplasty, Replacement, Knee/adverse effects , Knee Joint/surgery , Knee Prosthesis/adverse effects , Osteoarthritis, Knee/surgery , Retrospective Studies , Tibia/surgery
14.
China Journal of Orthopaedics and Traumatology ; (12): 43-48, 2022.
Article in Chinese | WPRIM | ID: wpr-928264

ABSTRACT

OBJECTIVE@#To investigate the effect of computer navigation gap balance technology on the recovery of lower limb function after total knee arthroplasty.@*METHODS@#The clinical data of 106 patients with knee osteoarthritis (OA) who underwent total knee arthroplasty from July 2018 to June 2019 were analyzed retrospectively. They were divided into measurement osteotomy group and space balance group according to different osteotomy techniques during total knee arthroplasty. There were 61 cases in osteotomy group, 24 males and 37 females;The age ranged from 45 to 77(63.35±4.26) years;According to K-L classification, 41 cases were grade Ⅲ and 20 cases were grade Ⅳ. intraoperative measurement osteotomy was performed. There were 45 cases in the gap balance group, 17 males and 28 females;Age 45 to 78(64.03±4.31) years;According to K-L classification, 29 cases were classified as grade Ⅲ and 16 cases as grade Ⅳ. computer navigation gap balance technology was implemented. The amount of intraoperative bleeding, operation time, incision length, hospital stay and postoperative complications were compared between two groups. The clinical efficacy was evaluated by Knee Society score(KSS) before operation and 12 months after operation.@*RESULTS@#Total of 106 patients were followed up for 12 to 18(20.38±3.25) months. There were significant differences in intraoperative bleeding and operation time between two groups(P<0.05). There was no significant difference in incision length and hospital stay between the two groups(P>0.05). At 12 months after operation, the total score of KSS in the gap balance group (173.59±14.50) was better than that in the osteotomy group (164.95±12.10)(P<0.05). There were no serious complications of poor prosthesis loosening between two groups during follow-up, and there was no significant difference in the incidence of other complications between two groups(P>0.05).@*CONCLUSION@#The application of computer navigation gap balance technology in total knee arthroplasty is conducive to the recovery of lower limb function in patients with OA, and there are no serious adverse complications and high safety.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Arthroplasty, Replacement, Knee , Computers , Knee Joint/surgery , Knee Prosthesis , Lower Extremity , Osteoarthritis, Knee/surgery , Retrospective Studies , Technology , Treatment Outcome
15.
Chinese Journal of Surgery ; (12): 268-272, 2022.
Article in Chinese | WPRIM | ID: wpr-927611

ABSTRACT

Component malrotation is one of the major causes of failure in total knee arthroplasty.Based on previous researches,Insall line has excessive external rotation tendency.Although Akagi line is the most recognized anatomical axis at present,it still has a certain tendency of internal rotation.The tibial posterior condylar axis is not suitable for symmetrical component and yet the Curve-on-Curve technique is not suitable for anatomic component.In addition,reference to any fixed anatomical markers cannot ensure the rotation consistency of tibiofemoral component in extension position.Although range of motion technique is beneficial to tibiofemoral rotation synchronization,its clinical effect seems to be unstable.Nevertheless,Patients can obtain good postoperative results with all major techniques.Before the recognized "gold standard" is defined,orthopedic surgeons can determine the rotation alignment of tibial component according to their most accustomed surgical method.With a deeper understanding of knee anatomy,biomechanics and kinematics,digital assistive technology may be expected to become a breakthrough in the tibial rotational alignment.


Subject(s)
Humans , Arthroplasty, Replacement, Knee/methods , Femur/surgery , Knee Joint/surgery , Knee Prosthesis , Osteoarthritis, Knee/surgery , Range of Motion, Articular , Tibia/surgery
17.
Rev. bras. ortop ; 56(1): 42-46, Jan.-Feb. 2021. tab, graf
Article in English | LILACS | ID: biblio-1288655

ABSTRACT

Abstract Objective To evaluate the wear of polyethylene in a Brazilian ultracongruent knee prosthesis with a rotating platform (Rotaflex, Víncula, Rio Claro, SP, Brasil). Methods We used the test method with the loading and preparation parameters mentioned in the standards regulation ISO 14243-1:2009, and the measurement methods mentioned in the standards regulation ISO 14243-2:2009, for the evaluation of the wear behavior of a Brazilian prosthesis with a rotating platform. The equipment used for the wear test was the ISO 14243-1 gait simulator (EndoLab, Riedering, Germany). Results After 10 million cycles, the evaluation of the polyethylene wear showed a regular appearance of surface wear at a mean rate of 2.56 mg per million cycles. Conclusion The wear of the polyethylene of the evaluated prosthesis was minimal after the tests performed and with safety limits higher than those recommended by biomechanical engineering.


Resumo Objetivo Avaliar o desgaste do polietileno de uma prótese de joelho brasileira ultracongruente de base rotatória (Rotaflex, Víncula, Rio Claro, SP, Brasil). Métodos Utilizou-se o método de ensaio com os parâmetros de carregamento e preparação citados na norma ISO 14243-1:2009, e os métodos de medição citados na norma ISO 14243-2:2009, para a avaliação do comportamento de desgaste de uma prótese nacional com base rotatória. O equipamento utilizado para o teste de desgaste foi o simulador de marcha ISO 14243-1 (EndoLab, Riedering, Alemanha). Resultados Após 10 milhões de ciclos, a avaliação do desgaste do polietileno mostrou uma aparência regular do desgaste da superfície com taxa média de 2,56 mg por milhão de ciclos. Conclusão O desgaste do polietileno da prótese avaliada foi mínimo após os ensaios realizados e com os limites de segurança superiores aos preconizados pela engenharia biomecânica.


Subject(s)
Prostheses and Implants , Prosthesis Failure , Arthroplasty, Replacement, Knee , Equipment and Supplies , Knee Prosthesis
18.
Rev. bras. ortop ; 56(1): 104-108, Jan.-Feb. 2021. tab, graf
Article in English | LILACS | ID: biblio-1288657

ABSTRACT

Abstract Objective This study aims to evaluate and correlate the nutritional status with potential complications during the immediate postoperative period of elderly patients surgically treated for proximal femoral fractures. Methods A prospective, cross-sectional analytical study with a quantitative approach, targeting patients aged 60 years old or more who were admitted to a hospital in Amazonas, Brazil, for surgical treatment of proximal femoral fractures. Surgical complications during the immediate postoperative period and their relationship with the nutritional status of the patient were determined using the mini nutritional assessment (MNA); in addition, the lymphocyte numbers and serum albumin levels were determined and correlated with the length of hospital stay. Results The sample consisted of 19 elderly patients, of both genders, with a mean age of 70.8 years. Most of the subjects (68.4%) were female. Malnutrition was diagnosed in 15.8% of the subjects using the body mass index (BMI) as, an anthropometric variable, and the MNA identified 31.6% of the subjects with malnutrition. Regarding total lymphocyte count, 100% of the sample showed a positive association with malnutrition in varying degrees; using serum albumin level as a parameter, malnutrition was identified in 89.4% of the subjects. Malnourished patients had the highest average length of stay. Surgical complications as surgical site infections occurred in 10.5% of the patients at risk of malnutrition. Conclusion This study revealed a higher rate of postoperative complications in elderly patients diagnosed with malnutrition.


Resumo Objetivo Avaliar e correlacionar o estado nutricional com possíveis complicações no pós-operatório imediato de pacientes submetidos a tratamento cirúrgico de fraturas de fêmur proximal. Métodos Estudo transversal prospectivo analítico e de abordagem quantitativa, tendo como população-alvo pacientes com idade igual ou superior a 60 anos, internados em uma instituição hospitalar no Amazonas, submetidos a tratamento cirúrgico de fraturas de fêmur proximal. Foram avaliadas as complicações cirúrgicas no pós-operatório imediato e sua relação com o estado nutricional através da mini avaliação nutricional (MAN), assim como a mensuração da contagem de linfócitos e albumina e a sua correlação com o tempo de internação. Resultados A amostra foi composta por 19 pacientes idosos, de ambos os sexos, com média de idade de 70,8 anos. A maioria dos pacientes (68,4%) eram do sexo feminino. Por meio da variável antropométrica índice de massa corporal (IMC), identificou-se a presença de desnutrição em 15,8% dos pacientes e, por meio da MAN, de 31,6%. Na avaliação do cálculo da contagem total de linfócitos, 100% da amostra apresentou associação positiva com desnutrição em graus variáveis e, fazendo-se uso da albumina sérica como parâmetro, a desnutrição foi identificada em 89,4%. Os pacientes desnutridos apresentaram a maior média de tempo de internação. As complicações cirúrgicas, por infecções do sítio cirúrgico, ocorreram em 10,5% nos pacientes em risco nutricional. Conclusão Neste estudo, observou-se maior índice de complicações no pós-operatório em idosos diagnosticados com desnutrição.


Subject(s)
Postoperative Complications , Prosthesis Design , Surgical Wound Infection , Prosthesis Failure , Arthroplasty, Replacement, Knee , Fractures, Bone , Knee Prosthesis
19.
Journal of Peking University(Health Sciences) ; (6): 877-882, 2021.
Article in Chinese | WPRIM | ID: wpr-942268

ABSTRACT

OBJECTIVE@#To evaluate the relationship between postoperative knee function and the sagittal position of tibial component in unicompartmental knee arthroplasty (UKA).@*METHODS@#We retrospectively enrolled the patients who underwent UKA from January 2016 to May 2020. They were assigned into 2 groups according to postoperative posterior tibial slope (PTS): the normal PTS group (PTS≥3° and PTS < 8°) and the abnormal PTS group (PTS < 3° or ≥8°). The patients were followed up for at least 12 months. The postoperative Knee Society Clinical Score (KSS-C), Knee Society Functional Score (KSS-F) and knee range of motion (ROM) were compared between the two groups.@*RESULTS@#A total of 72 patients (82 knees) were included with 51 patients (58 knees) in PTS normal group and 21 patients (24 knees) in PTS abnormal group. All the patients were followed up with median of 23.6 months. There was no significant difference in the general data [gender, age, body mass index (BMI)], pre-operative knee range of motion, preoperative KSS-C score and KSS-F score (P > 0.01). The KSS-C score, KSS-F score, and knee range of motion significantly improved after surgery (P < 0.01) for all the patients. The postoperative KSS-C score in normal PTS group (88.76±2.79) was significantly higher than the KSS-C score in abnormal PTS group (84.42±3.35, P < 0.01), but no significant difference between the 2 groups was observed in postoperative KSS-F score and knee range of motion (P > 0.01). In addition, there was no correlation between the change of PTS and postoperative KSS-C score (r=-0.034, 95%CI: -0.247 to 0.186, P = 0.759), KSS-F score (r = -0.014, 95%CI: -0.238 to 0.198, P = 0.901) and knee range of motion (r= 0.045, 95%CI: -0.214 to 0.302, P = 0.686).@*CONCLUSION@#The posterior tibial slope between 3° and < 8° can be recommended to improve knee joint function in mobile UKA, and excessive or insufficient PTS should be avoided.


Subject(s)
Humans , Arthroplasty, Replacement, Knee , Knee Joint/surgery , Knee Prosthesis , Osteoarthritis, Knee/surgery , Range of Motion, Articular , Retrospective Studies , Treatment Outcome
20.
Journal of Peking University(Health Sciences) ; (6): 293-297, 2021.
Article in Chinese | WPRIM | ID: wpr-942176

ABSTRACT

OBJECTIVE@#To analyze the preoperative influencing factors of varus after Oxford unicompartmental knee arthroplasty.@*METHODS@#A total of 660 patients (767 knees) undergoing Oxford unicompartmental knee arthroplasty in adult joint reconstruction surgery department of Beijing Jishuitan Hospital from January 2018 to December 2019 were retrospectively analyzed. Inclusive criteria: diagnosis was osteoarthritis, single compartment lesions in the medial side of the knee; preoperative flexion deformity was less than 10°, active range of motion was greater than 90°; preoperative X-ray full-length images of both lower limbs showed less than 15° varus (Noyes method); anterior cruciate ligament was well functioned, The cartilage of lateral compartment of knee joint was intact.@*EXCLUSION CRITERIA@#combined with other inflammatory arthropathy; combined with extraarticular deformity; previous knee surgery history. The average age of the patients was (64.4±8.1) years, including 153 males and 497 females. The degree of post-operative varus was measured with Noyes method. The total patients were divided into varus group (Noyes≥3 °) and normal group (Noyes < 3 °). Gender, age, body mass index (BMI), range of motion (ROM), preoperative flexion deformity (FD), American Knee Society pain score (AKS) and American Knee Society function score (AKS function) were recorded. The standard anteroposterior and lateral X-ray films of knee joint and full-length lower extremity kinematic line films were taken by Sonialvision Safine Ⅱ (Shimadzu, Japan) multi-function digital tomography system. The image was measured by picture archiving and communication system (PACS). The following angles were measured preoperative Noyes angle, lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA) and joint line converge angle (JLCA) were measured and analyzed.@*RESULTS@#Gender(P=0.346), operative side (P=0.619), age (P=0.746), BMI (P=0.142), preoperative ROM (P=0.102), preoperative knee pain score (P=0.131) and functional score (P=0.098) were not risk factors for postoperative varus. The influencing factors of postoperative varus were preoperative MPTA < 84 ° (P= 0.018, OR= 3.712, 95%CI: 1.250-11.027), preoperative Noyes > 5°(P=0.000, OR= 3.105, 95%CI: 1.835-5.254), preoperative FD > 5° (P= 0.001, OR=1.976, 95%CI: 1.326-3.234). Pre-operative LDFA (P=0.146) and preoperative JLCA (P= 0.709) had no significant effect on postoperative kinematic line.@*CONCLUSION@#Patients with severe preoperative varus, especially those with varus deformity mainly from the tibial side, and those with preoperative flexion deformity are more prone to get varus lower extremity kinematic line after Oxford unicompartmental knee arthroplasty.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Arthroplasty, Replacement, Knee , Knee Joint/surgery , Knee Prosthesis , Multivariate Analysis , Osteoarthritis, Knee/surgery , Range of Motion, Articular , Retrospective Studies
SELECTION OF CITATIONS